The 10-meter optical input and electrical output gas absorption cell is used for various gas spectral analysis and detection. The optical path structure of the gas cell uses the self-patented design, the flat wave gas cell (SlimBoss Gas Cell) with excellent optical stability, and the auxiliary and high-stability optical packaging structure, which is mainly composed of the gas cavity, reflector, standard optical fiber connector, gas inlet and outlet, and shockproof base. The unique suspension optical path design has excellent vibration and temperature stability, can work stably in various complex environments, and is very suitable for online real-time detection of various gases. It has low system noise and can be applied to trace gas analysis..
产品特点The air chamber structure is stable and resistant to vibration and external extrusion、 The air chamber is small in size, compact in structure, and easy to carry、 The effective optical path is long、 The input uses standard single-mode optical fiber, and the output uses PD or optical fiber
产品货号H80060002
应用领域Air pollutant monitoring、 Coal flue gas emission monitoring、 Waste incineration emission monitoring、 Chemical park pollutant monitoring
产品单价联系客服询价
到货日期请咨询客服获得货期
产品库存请咨询客服
Daisy
电话:18602170419
邮箱:moli@microphotons.com
相关产品
Parameter
Parameters | Technical specifications |
Effective optical path | 10m |
Wavelength range | 1960-2400nm |
Insertion loss | ≤2dB |
Maximum input optical power | 2mW |
Fiber type | nufernSM1950 optical fiber |
Output type | PD |
Reflector | Dielectric film |
Pressure range | ≤0.3MPa |
Gas interface | Φ6 straight-through |
Gas volume | About 69mL |
Total product weight | About 450g |
Shell material | 6061 |
Operating temperature | -20℃-70℃ |
Storage temperature | -40℃-85℃ |
PD parameter
Parameters | Symbol | Min | Typical | Max | Unit |
Storage temperature | Tstg | -50 | - | 125 | °C |
Operating temperature | Top | -40 | 25 | 85 | °C |
PD reverse bias voltage | VR | - | - | 1 | V |
Soldering temperature | Tsold/t | 260/10 | - | - | °C/s |
Wavelength range | λp | 900 | - | 2600 | nm |
Photosensitive surface | Φ | 0.3 | mm | ||
Responsivity | Re=λp | 1 | - | - | A/W |
Dark current | ID(TC=+25°C/VR=0.5V) | 0.4 | - | 4 | uA |
Capacitance | CJ(VR=1V,f=1MHz) | - | 50 | 100 | pF |
10 meter optical path miniaturization chamber usage test
Using 2004nm and 2327nm DFB lasers, we built a TDLAS gas absorption system and measured the signal through the gas chamber.
For 2004nm DFB laser, it is used to measure the gas absorption concentration of CO2:
2004nm DFB laser measurement of CO2 gas absorption concentration amplitude
Compare with our database data:
For 2327nm DFB laser, used to measure the gas absorption concentration of CO:
2327nm DFB laser measurement of CO gas absorption concentration amplitude
Compare with our database data:
Verify that this absorption peak is the absorption peak of CO gas we measured at 2327nm
By comparison, we can find that after using the 10-meter miniaturized gas chamber, the measured gas absorption molecular amplitude becomes larger as the optical path lengthens, and a lot of detection noise is filtered out, the interference to the signal becomes smaller and smaller, and the measurement accuracy is improved.
Ordering Information